Condition of Auxiliary Condenser Dump Valve
![]() |
| Condition of Auxiliary Condenser Dump Valve |
Signal from the condenser gravitational pressure tank to the automatic level control is not right, necessary to test tap of the tank condenser
Pressure gauge out automatic level control signal from the input signal on the pressure gauge valve positioner is not worth the same, needs to be calibrated pressure gauge out automatic level control signal and the valve positioner input signal
Signal range of automatic level control has not ruled or open the right scale on the pressure out of the positioner to the valve diaphragm, need calibration accuracy trigger input signal with the output pressure of the positioner valve to the diaphragm valve.
Pressure gauge on the incoming supply valve positioner is not working, need replacement pressure gauge.
There are leaks air pressure in the automatic level control unit, need further improvement
![]() |
| Repairing and Calibration Auxiliary Condenser Dump Valve |
Data equipment as follows:
1. Automatic Level Control Filter Regulator (need to be calibrated because the effect on supply pressure effect on the sensitivity of the signal settings and setting levels)- Brand : SMC
- Type : IW 215-02
- Max. input press : 1,0MPa
- Output press : 0,02 ~ 0,5MPa
- Pressure Gauge : SMC, range 0 – 4 kg/cm2 or 0 – 60PSI, dia 1,65”, connection 0,4” back connection type (need to be calibrated).
2. Automatic Level Control
3. Positioner Valve Filter Regulator (need to be calibrated).
- Brand : Nakakita Seisashuko
- Type
- Supply Pressure Gauge : NKS, range 0 – 3 kg/cm2, dia 2”, connection 0,5” back connection type (need to be calibrated)
- Output Pressure Gauge: NKS, range 0 – 2 kg/cm2, dia 2”, connection 0,5” back connection type(need to be calibrated)
![]() |
| Positioner Valve/ Level Control Valve for Aux Condenser |
- Brand : Nakakita Seisashuko
- Type : NS770C
- Connection : PT1/4
- Inlet pressure : 10kg/cm2(max)
- Outlet pressure : 3 kg/cm
- Not pressure gauge
- Brand : Nakakita Seusashuko
- Type : NS 7345 D
- Loading Press : 0,2 – 1.0 Kg/cm2
- Air Supply Press: 2,4 Kg/cm2
- Output Press : 0,4 – 2 Kg/cm2
- Supply Pressure Gauge: NSK, range 0 – 3 kg/cm2, dia. 1,65”, connection 0,3”, under connection type (need to be calibrated).
- Outlet Pressure Gauge : NSK, range 0 – 2 kg/cm2, dia. 1,65”, connection 0,3”, under connection type (need to be calibrated).
- Inlet Signal Pressure Gauge: NSK, range 0 – 2 kg/cm2, dia.1,65”, connection 0,3”, under conection type (need to be calibrated).
- Brand : Nakakita Seusashuko (need to be calibrated).
- Nominal Bore : 80A
- Body rating : 5
- Body Trim : MTLFC20/S.STL
- Construction : 5 K
- Rated : AB 46/ AC 36
- Serial Number : 89K3364
- Caracteristic : LTN
- Travel : 30mm
- Airless : CASCAD.TK.OPEN
- Supply press. : 2,4 kg/cm2
- Sprink Range : 0,4 – 2 kg/cm2