Problems that occur damage to the synchronization panel
Generator 1 failed Synchrone to Generator 2, after a few
seconds do synchronize MCCB Generator 1 Trip.
Possible errors occur on the AVR generator 1 or 2, also at
supporting components such as: Reverse
Power Relay.
![]() |
| Generator |
The work that has been done:
1. Check the voltage on the generator, through the settings
made on the AVR Generator 1 and Generator 2. Change the settings by turning a
few degrees at a variable resistor, need special labeling before doing it with
a marker that is not easily lost.
This reel considering changes that could be
made more aggravating circumstances for AVR settings.
2. Check the second frequency generator, are like that done at the same point above, several types of
AVR presents some variable resistor for setting the duty of each such change in
voltage and frequency changes.
3. Setting the output voltage of the generator 1 through the
AVR, does not solve the problem. Perform the next step, check the technical
components such as Reverse Power Relay, Control Sync and others.
4. Check Reverse Power Relay, detectable damage to the
Reverse Power Relay generator unit 1
The next solution;
- PH 1/3 6 / 4W Reverse Power Trip
- Type: M200 RP1
- Series No. : 240V L / N 50/60 Hz 6A
- Operation: Energize On Trip
Detail project:
Vessel
|
ASL Glory
|
Equipment type
|
Sinchronize Panel
|
Service Issue
|
Error proses synchronize
|
Location
|
ASL Shipyard
|